Talk to us
Deep Pile Foundations use all three types of MultiPoles. These can be up to 22m long and may be joined in order to penetrate great depths. All you need is an identified bearing layer that’s at least 3m thick.
We’ll install your foundations using high frequency vibration. This process leaves pile tops undamaged and has minimal effect on neighbouring properties.
We’ll then test your foundations using either the Hiley Formula for residential foundations, or a Pile Driving Analyser (PDA) for commercial foundations.
• Installation time frame subject to the size of the poles and the quantity and ground conditions.
• Piles can reach great depths.
• Non-damaging, non-disturbing installation.
• Uses award-winning MultiPoles.
• PS1, PS3 and PS4 provided.
Our Deep Pile Foundations can support your enhanced concrete slab or timber floor.
After a superior option? We can design your Deep Pile Foundations to have a dependable pile bearing capacity of 500kN or more, subject to ground conditions. We can also design them to cope with 300mm of lateral movement.
DOWNLOAD
TDPF01 – Deep Pile Foundations tech sheet
TDPF02 – Deep Pile Foundations Static Load Testing tech sheet
DOWNLOAD
CDPF01 – New commercial building case study
DOWNLOAD
CDPF02 – Avon River Precinct case study
DOWNLOAD
CDPF03 – Dairy factory expansion case study
DOWNLOAD
CDPF04 – Indoor swimming pool case study
DOWNLOAD
CDPF05 – Irrigation tank & silo facility case study
DOWNLOAD
CDPF06 – Residential housing Otahuhu case study
DOWNLOAD
CDPF07 – Residential townhouse Manurewa case study
DOWNLOAD
CDPF08 – Apartment buildings Otahuhu case study
DOWNLOAD
CDPF09 – New Mitre 10 Beachlands case study
DOWNLOAD
view TECH SHEETs
VIEW CASE STUDies
Technical category | Type of MultiPole used | Typical pole diameter | Typical pole length | Typical pole spacing | Typical installation method | |
---|---|---|---|---|---|---|
Residential foundations | TC2 & TC3 | SED
Uglie UniLog |
150–250mm | 1.0–22.0m Poles can be joined to reach greater depths |
2.0–4.0m | High frequency vibration and pile driving |
Commercial foundations | TC2 & TC3 | SED
Uglie UniLog |
250–300mm | 1.0–22.0m Poles can be joined to reach greater depths |
2.0–4.0m | High frequency vibration and pile driving |
Foundation system | Technical Category | Type(s) of MultiPole used | Typical pole diameter | Typical pole length | Typical pole spacing | Typical installation method | |
---|---|---|---|---|---|---|---|
Deep Pile Foundations | Residential foundations | TC2 & TC3 | SED, Uglie, UniLog | 150–250mm | 1.0–22.0m Poles can be joined to reach greater depths | 2.0–4.0m | High frequency vibration and pile driving |
Commercial foundations | TC2 & TC3 | SED, Uglie, UniLog | 250–300mm | 1.0–22.0m Poles can be joined to reach greater depths | 2.0–4.0m | High frequency vibration and pile driving | |
Ground Improvement | Residential foundations | TC2 & TC3 | Uglie | 200–300mm | 2.4–4.8m | 1.0–1.5m | High frequency vibration and pile driving |
Commercial foundations | TC2 & TC3 | Uglie | 300mm | 6.0–15.0m | 1.0–2.5m | High frequency vibration and pile driving | |
Raft Foundations | Residential foundations | TC2 & TC3 | UniLog | 275mm for beams and 180mm for jack studs | To suit house dimensions | 1.0–4.0m | 5 tonne excavator |
Commercial foundations | TC1, 2, 3 | UniLog | 275mm for beams and 180mm for jack studs | To suit building dimensions | 1.0–4.0m | 5 tonne excavator | |
Road foundations | TC1, 2, 3 | UniLog | 275mm for beams and 180mm for jack studs | To suit building dimensions | 1.0–4.0m | 5 tonne excavator |
First of all, we’ll need a geotechnical report for your site. If you don’t have one of these, we’ll help you get one.
This will be based on your geotechnical report, and could involve the customisation of one or more of our existing foundation systems.
Our installation processes are fast and efficient. They’ll have minimal impact on neighbouring properties and will leave your site undamaged.
Issuance of PS3 and PS4 documentation.
You now have excellent foundations to build on!